If alternating with temp, may be temporary condition. Sensor plugged into jack B is not working. Sensor plugged into jack A is not working. SE Spa operating in Standard-in-Economy Mode. Press any Button except "Jets 1" to Exit and Return to Normal Operation. This Mode allows the User to Replace or Clean a Pressure Side Filter Cartridge without Equipment turning ON unexpectedly. SBY Standby - The Spa is Operating in the "Standby" (SbY) Mode.Īll Automatic Spa System Functions are Disabled so that Pumps and Blower will not turn ON Automatically. Contact your Dealer or Service Organization. Note: If you do Not have an ORP Sensor installed in the Spa System, you should Never get this Message. Add Sanitizer according to Manufacturers Instructions. With an ORP Sensor Installed in the System, the Sanitizer Level is Below 740 and needs to be Corrected. SAL Sanitizer Low - At the ORP Sensor, the "Sanitizer Level is Low" (SAL). SAH Sanitizer High - Time to Check "Sanitizer Level Reminder" (rSA). All Reminder Messages can be Disabled through the Topside Panel Users Menu. Rt9 GFCI test - Time to "Test GFCI Reminder" (rtg).Īppears Every 30 Days*.

Test and Adjust Sanitizer Level per Manufacturers Instructions. RSAĜheck Sanitizer - Time to Check "Sanitizer Level Reminder" (rSA).Īppears Every 7 Days*. * Note: The Balboa Default Interval is 7 Days, but some Spa Brands or Models may be Different. Test and Adjust pH Level per Manufacturers Instructions. RPHĜheck PH - Time to Check "pH Level Reminder" (rPH).Īppears Every 7 Days*. * Note: The Balboa Default Interval is 30 Days, but some Spa Brands or Models may be Different. Remove, Clean, and Reinstall Spa Filter Cartridge per Manufacturers Instructions. RCLĜlean Filter - Time to "Clean Filter Reminder" (rCL).Īppears Every 30 Days*. * Note: The Balboa Default Interval is 365 Days, but some Spa Brands or Models may be Different.
#Hydro quip spa error codes install#
Install a New Filter Cartridge per Manufacturers Instructions. RCH New Filter - Time to "Change Filter Reminder" (rCH)Īppears Every 365 Days*.
_XL.jpg)
Some Spa Brands or Models may have this Message Enabled, and the Interval between these Messages will be whatever the Spa Manufacturer has selected. Note: The Balboa Default is to have this Message Disabled. Install a New Mineral Cartridge per Manufacturers Instructions. RCAĜhange Mineral Cartridge - Time to "Change Mineral Cartridge Reminder" (rCA)

Pr When spa is first actuated, it will go into Priming Mode. Pd Power supply, unit running on battery backup One sensor has detected 118º F at heater. Heater is shut down, but other spa functions run normally. (Displays on the 5th occurrence of "HFL" message with 24 hours). ILOC Interlock failure - possible pump or ozone spike. ICE Potential freeze condition has been detected Check for All of the following Conditions: HFL Substantial difference between temperature sensors detected. The spa has determined that a GFCI is NOT properly installed in the circuit providing power to the spa, because an attempt was made to trip the GFCI and the expected power shut-down did not occur. GFI GFCI Failure - The Control System Could Not Trip the "GFCI" (gFI). Spa is shut down.įlo Improper flow or pressure switch malfunction (Displays on third occurrence of "dr" message).

(Displays when first powered up after refill).ĭry Inadequate water detected in heater.